Sterile
Medical grade
Pre-cut to 15 cm lengths
Individually packaged
Ready to use
Fit all pump models
Direct delivery of test agents into any target tissue or organ
Delay delivery of test agents to allow for a surgical recovery period
Infuse for a shorter period using a longer duration pump
Infuse a smaller volume of solution
Create a time-patterned delivery of an agent
Silicone patch facilitates anchoring to tissue
Silicone material is very flexible and less traumatic to vessels
Bevel tip if desired for easier insertion into vessels
ETO sterilized
Retention beads at 3.81, 5.08, and 7.62 cm from the tip facilitate anchoring to tissue
Medical grade polyurethane softens at body temperature
Fits directly to pump (no step-up needed)
Retention beads at 3.81, 5.08, and 7.62 cm from the tip facilitate anchoring to tissue
Medical grade, tapered polyurethane minimizes kinking
Radio-opaque material and smooth surface minimize clotting
Lumen maintains consistent ID, so that the catheter can be shortened without compromising its tight fit onto pump
Designed for occipital insertion
Includes a Teflon coated stylet for easier placement
Protected tubing junction minimizes kinking at exit point from intrathecal space
Shorter length for lumbar insertion
Includes a Teflon coated stylet for easier placement
Protected tubing junction minimizes kinking at exit point from intrathecal space
Retention beads at 13 and 38 mm from the tip facilitate anchoring to tissue
Catheter tip optimum for use with other small vessels (e.g., femoral, carotid, etc.)
Marked at 9 and 11 mm to simplify adaptation for < 25 and 25-30 gram animals respectively
Retention beads at 13 and 38 mm from the tip facilitate anchoring to tissue
Catheter tip optimum for use with other small vessels (e.g., femoral, carotid, etc.)
Marked at 9 and 11 mm to simplify adaptation for < 25 and 25-30 gram animals respectively
ALZET connection can be trimmed to achieve smaller lengths
Catheter tip optimum for use with other small vessels (e.g., femoral, carotid, etc.)
Retention beads at 13 and 35 mm from the tip facilitate anchoring to tissue
Marked at 9 and 11 mm to simplify adaptation for < 25 and 25-30 gram animals respectively
ALZET connection can be trimmed to achieve smaller lengths
Catheter tip optimum for jugular cannulation
Retention beads at 13 and 35 mm from the tip facilitate anchoring to tissue
Marked at 9 and 11 mm to simplify adaptation for < 25 and 25-30 gram animals respectively
Distal end can be trimmed
Includes a Teflon coated stylet for easier placement
Catheter is provided sterile
Peritoneal/Gastric delivery
Peritoneal delivery via subcutaneous pump
Easier pump replacement
Use larger pump for IP delivery in mice
Fenestrations over Silicone tip for greater drug distribution
Movable suture bead for optimum adjustment of inserted catheter section
Flexible Silicone section minimizes tissue trauma
Polyethylene section provides optimum fit to all ALZET pump models; can be cut to desired length
Stress relief catheter junction prevents kinking and improves patency